1. RF Communication Test Sets Products
  2. sku: 163755116260333
  3. WILTRON ANRITSU 54147A-A2

WILTRON/ANRITSU 54147A-A2 Scalar Network Analyzer

54147a-a2 Wiltron Anritsu Mhz To Ghz Scalar Network Analyzer Options

( Brand: Wiltron/anritsu ), ( Manufacturer Part Number: 54147A-A2 ), ( Bundle Listing: No ), ( Country/region Of Manufacture: United Kingdom ), ( Type: 10 Mhz To 20 Ghz Scalar Network Analyzer )

Review WILTRON/ANRITSU Mhz Ghz Scalar Network Analyzer Options Wiltron anritsu

The 54147a-a2 Wiltron Anritsu 10-20 GHz Scalar Network Analyzer is a high-performance test instrument designed for a wide range of applications in the RF and microwave industry. This network analyzer offers a frequency range of 10 MHz to 20 GHz, making it suitable for testing a variety of components and systems, including filters, amplifiers, antennas, and transmission lines.

The 54147a-a2 features a scalar network analyzer (SNA) design, which allows for the measurement of both magnitude and phase information. This provides a more comprehensive understanding of the electrical properties of the device under test (DUT), enabling more accurate and reliable results. The SNA design also enables the measurement of complex impedance, which is important for the design and optimization of microwave circuits.

The instrument offers a maximum measurement bandwidth of 2 GHz, which allows for fast and accurate measurements, even for fast-changing signals. It also has a high dynamic range of 110 dB, which enables the measurement of both low-level and high-level signals with high accuracy. The 54147a-a2 also features an internal calibration system, which ensures accurate and repeatable measurements, even in challenging environments.

The 54147a-a2 comes with a large, high-resolution touchscreen display, which provides easy-to-read results and intuitive operation. The instrument also offers a variety of measurement options, including S11, S21, S22, S12, and Y parameters, as well as time domain reflectometry (TDR) and network analysis software.

In addition, the 54147a-a2 is equipped with built-in RF sources, including a built-in vector network analyzer (VNA) and a built-in frequency synthesizer, which enables the generation of various RF signals for testing purposes. It also has built-in RF amplifiers, which can be used to boost the power level of the RF signals for testing high-power devices.

The 54147a-a2 is compact and lightweight, making it easy to transport and use in the field. It is also designed for ruggedness and durability, with a sturdy construction and a protective case. The instrument is also energy-efficient, with a low power consumption, making it a cost-effective choice for users who need a high-performance network analyzer with a wide frequency range.

In summary, the 54147a-a2 Wiltron Anritsu 10-20 GHz Scalar Network Analyzer is a high-performance test instrument designed for a wide range of RF and microwave applications. It offers a scalar network analyzer design, a large touchscreen display, a variety of measurement options, built-in RF sources and amplifiers, and is compact, lightweight, rugged, and energy-efficient. It is a powerful and reliable tool for engineers and technicians who need to measure and characterize RF and microwave components and systems with high accuracy and precision.

Pros of buying a 54147a-a2 54147a Wiltron Anritsu 10-20 GHz scalar network analyzer:

1. High-performance: This analyzer offers a frequency range of 10-20 GHz, which is suitable for a wide range of applications, including microwave and millimeter-wave design and testing.

2. Accuracy: The analyzer has a high accuracy of /- 0.04 dB and /- 1.0 degrees, which ensures reliable and precise measurements.

3. Built-in options: The analyzer comes with built-in options such as vector network analysis, time domain analysis, and parametric analysis, which can increase the flexibility and capabilities of your testing setup.

4. Durable construction: The analyzer is built with high-quality materials and has a robust design, which can withstand harsh environmental conditions and ensure long-term reliability.

Cons of buying a 54147a-a2 54147a Wiltron Anritsu 10-20 GHz scalar network analyzer:

1. High cost: The analyzer is a high-end instrument, and its price reflects its performance and capabilities. It may be out of budget for some users.

2. Complexity: The analyzer has a lot of features, and it may take some time to learn how to use it effectively. The user manual and technical support can be helpful in this regard.

3. Size and weight: The analyzer is a large and heavy instrument, which can make it difficult to transport and use in the field.

Recommendation:

The 54147a-a2 54147a Wiltron Anritsu 10-20 GHz scalar network analyzer is a high-performance instrument that can provide accurate and reliable measurements for microwave and millimeter-wave design and testing. It is suitable for users who require advanced testing capabilities and are willing to invest in a high-end instrument. However, its high cost and complexity may make it less suitable for users with limited budgets or technical expertise. If you have the resources and need the capabilities of this analyzer, it could be a great investment for your lab or business.

Details:

This unit has been well protected in its hard case. 5 inch disk drive: yes intelligent markers: glib as standard: mean time between failure mt bf: 10,000 hours condition: pulled from working system, used very clean unit with front plastic cover.

Wiltron Anritsu model 54147A 10 mhz to 20 ghz scalar network analyzer includes protective hard case test kit part number: 54147A-A2: the series integrated has built in crystal referenced sources provide an economical and compact solution.

This analyzer is ideal for production of devices such as filters and amplifiers from 1mhz to 50ghz.

No cracks or breaks in case. This units fan is very noisy and may need to be lubricated or replaced.

Last calibration date is: 11-Jul-1997 this analyzer is beyond its warranty period.

Other: options installed: - 01 step attenuate 05 r channel 07 def sold as shown in photos with ac power cord, long RF test cable, kit 560-7n50b 10mhz-20ghz detector, 5400-6n50 1 mhz to 3ghz Sr auto tester 50 ohm and various connector cable fittings.

Hard case and user documentation included.

Optional software adds distance to fault measurements for field testing of wave guides, cables and antennas, relative group delay economic filter characterization precision return loss that up 20db reactivity improvement Sr.

part #: 54147aa2 price

  • $5500.00

specifications celltesequ:

  • brand: Wiltron/anritsu
  • mpn: 54147a-a2
  • bundle listing: No
  • country/region of manufacture: United Kingdom
  • type: 10 Mhz To 20 Ghz Scalar Network Analyzer

Seller celltesequ:

  • rating 02-08-19: 100.0%
  • zipcode: 32305
  • # feedbacks 02-08-19: 4876
  • city: Tallahassee, Florida

Shipping celltesequ:

  • handling: days
  • type: Calculated
  • cost: $2.95

Payments celltesequ:

  • PayPal

Returns celltesequ:

  • time: 60 Days
  • type: Money Back
  • paid by: Seller
  • policy: returns accepted

General celltesequ:

  • Analyzers Data Acquisition > RF Communication Test Sets
  • in stock: Yes
  • condition: Used

Offer celltesequ:

  • bids: 0
  • best offer: true
  • Sold: 0
  • quantity: 1
  • Started: February 8, 2019, 1:04 pm
bundle listing: no, country/region of manufacture: united kingdom, type: 10 mhz to 20 ghz scalar network analyzer,
category: business & industrial > analyzers data acquisition > rf communication test sets, sku: 163755116260333,
Wiltron/anritsu 54147A-A2 Is Similar To:
  • (42% similar) Here is a link to our test equipment store. Please as it may be fresh inventory waiting to listed or we'll glad find for you at the best price possible and put up an listing. Its excellent match makes it ideal as a reference for fault location measurements on scalar network analyzers. To get a real-...(November 12th, 2018)
  • (28.9% similar) Wiltron anritsu 34US50 34YV50 3/3 4UK50...(June 12th, 2019)
  • (30.1% similar) This item has a current calibration. Please as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an listing for you. To db frequency reference aging 1 ppm yr accuracy 2 ppm internal memory trace memory 40 maximum instrument con ...(June 29th, 2015)
  • (26.4% similar) Wiltron anritsu SC3834 item 002NO reserve...(June 12th, 2019)
  • (28.9% similar) ...(July 15th, 2019)
  • (40.7% similar) 12N75 matching adapter, 50 ohm n m x 75, loss...(July 17th, 2019)
  • (39.6% similar) Their excellent match makes them ideal as a reference for fault location measurements on scalar network analyzers. This open standard is brand new, in original packaging. Anritsu wiltron 24K50, 92MM male open standard, dc to 40GHZ. Free shipping in the us...(August 30th, 2019)
  • (42.9% similar) These standards have been used very little. Free shipping in the us. Anritsu wiltron 23K50, their excellent match makes them ideal as a reference for fault location measurements on scalar network analyzers. 92MM male short standard, dc to 40GHZ. Some minor scratches on body due to use. These ...(September 1st, 2019)
  • (41.7% similar) Condition is used, performance as. K connector, these are part of the anritsu wiltron 3652 calibration kit. For sale is a 23KF50 female short, dc to 40GHZ...(September 8th, 2019)
  • (41% similar) Free shipping in the us. 85MM male short termination. Their excellent match makes them ideal as a reference for fault location measurements on scalar network analyzers. These standards have been tested on our 67GHZ Pan measurements are available upon request. This short has been used very little. ...(September 15th, 2019)
celltesequ logo
1 offer $5500.00 USD
  • Used. Offer #1 priced at $5500.00 + $3000.00 shipping estimate = $8500.00* total. CW Provides single frequency output. Manual,Power Cord.+$3000.00 shipping

Copyright © celltesequ.com